Immigrant Roofer Electrocuted When an Aluminum Ladder Platform Hoist Contacted Overhead Power Line
Massachusetts Case Report: 10MA019
July 18, 2011
SUMMARY
On August 3, 2010 a 23-year-old male laborer (victim) was electrocuted and two co-workers were severely shocked when the 32-foot aluminum ladder that was part of a ladder platform hoist came in contact with energized overhead power lines. The victim and the two co-workers were in the process of raising the ladder from a horizontal position on the ground to a vertical position against a building. While raising the ladder to the vertical position, the workers lost their footing and the ladder fell towards and came in contact with energized overhead power lines. Two co-workers were shocked and thrown to the ground. The victim was electrocuted and the ladder fell to the ground landing on top of him. Once the two co-workers regained mobility, they went to assist the victim. One of the coworkers placed a call for emergency medical services (EMS) and then placed a second call to the employer. The local police arrived followed by EMS within minutes of the call. The victim was transported to a local hospital where he was pronounced dead. The Massachusetts FACE Program concluded that to prevent similar occurrences in the future, employers should:
Immigrant Roofer Electrocuted When an Aluminum Ladder Platform Hoist Contacted Overhead Power Line
[PDF 423 KB]
- Page last reviewed: November 18, 2015
- Page last updated: October 15, 2014
- Content source:
- National Institute for Occupational Safety and Health Division of Safety Research