n-Butyl acetate
Synonyms & Trade Names
Butyl acetate, n-Butyl ester of acetic acid, Butyl ethanoateExposure Limits
NIOSH REL
TWA 150 ppm (710 mg/m3) ST 200 ppm (950 mg/m3)OSHA PEL
TWA 150 ppm (710 mg/m3) See Appendix GPhysical Description
Colorless liquid with a fruity odor.Molecular Weight
116.2Boiling Point
258°FFreezing Point
-107°FSolubility
1%Vapor Pressure
10 mmHgIonization Potential
10.00 eVSpecific Gravity
0.88Flash Point
72°FUpper Exposive Limit
7.6%Lower Explosive Limit
1.7%Incompatibilities & Reactivities
Nitrates; strong oxidizers, alkalis & acidsExposure Routes
inhalation, ingestion, skin and/or eye contactSymptoms
irritation eyes, skin, upper respiratory system; headache, drowsiness, narcosisTarget Organs
Eyes, skin, respiratory system, central nervous systemPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet (flammable)
Change:No recommendation
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Water flush promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH/OSHA
Up to 1500 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)*
(APF = 10) Any supplied-air respirator*
Up to 1700 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)*
(APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus