Cyclohexanol
Synonyms & Trade Names
Anol, Cyclohexyl alcohol, Hexahydrophenol, Hexalin, Hydralin, HydroxycyclohexaneExposure Limits
NIOSH REL
TWA 50 ppm (200 mg/m3) [skin]OSHA PEL
TWA 50 ppm (200 mg/m3) See Appendix GPhysical Description
Sticky solid or colorless to light-yellow liquid (above 77°F) with a camphor-like odor.Molecular Weight
100.2Boiling Point
322°FMelting Point
77°FSolubility
4%Vapor Pressure
1 mmHgIonization Potential
10.00 eVSpecific Gravity
0.96Flash Point
154°FUpper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
Strong oxidizers (such as hydrogen peroxide & nitric acid)Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contactSymptoms
irritation eyes, skin, nose, throat; narcosisTarget Organs
Eyes, skin, respiratory systemPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Water wash promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH/OSHA
Up to 400 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)*
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)*
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 10) Any supplied-air respirator*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus