Dibutyl phosphate
Synonyms & Trade Names
Dibutyl acid o-phosphate, Di-n-butyl hydrogen phosphate, Dibutyl phosphoric acidExposure Limits
NIOSH REL
TWA 1 ppm (5 mg/m3) ST 2 ppm (10 mg/m3)OSHA PEL
TWA 1 ppm (5 mg/m3) See Appendix GPhysical Description
Pale-amber, odorless liquid.Molecular Weight
210.2Boiling Point
212°F (Decomposes)Freezing Point
?Solubility
InsolubleVapor Pressure
1 mmHg (approx)Ionization Potential
?Specific Gravity
1.06Flash Point
?Upper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
Strong oxidizersExposure Routes
inhalation, ingestion, skin and/or eye contactSymptoms
irritation eyes, skin, respiratory system; headacheTarget Organs
Eyes, skin, respiratory systemPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:No recommendation
Provide:Quick drench
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH/OSHA
Up to 10 ppm:
(APF = 10) Any supplied-air respirator
Up to 25 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
Up to 30 ppm:
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus
- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source:
- National Institute for Occupational Safety and Health (NIOSH) Education and Information Division