Ferrovanadium dust
Synonyms & Trade Names
FerrovanadiumExposure Limits
NIOSH REL
TWA 1 mg/m3 ST 3 mg/m3 [*Note: The REL also applies to Vanadium metal and Vanadium carbide.]OSHA PEL
TWA 1 mg/m3 See Appendix GPhysical Description
Dark, odorless particulate dispersed in air. [Note: Ferrovanadium metal is an alloy usually containing 50-80% vanadium.]Molecular Weight
106.8Boiling Point
?Melting Point
2696-2768°FSolubility
InsolubleVapor Pressure
0 mmHg (approx)Ionization Potential
NASpecific Gravity
?Flash Point
NAUpper Exposive Limit
NALower Explosive Limit
NAMinimum Explosive Concentration
1.3 g/m3Incompatibilities & Reactivities
Strong oxidizersExposure Routes
inhalation, skin and/or eye contactSymptoms
irritation eyes, respiratory system; In Animals: bronchitis, pneumonitisTarget Organs
Eyes, respiratory systemPersonal Protection/Sanitation
(See protection codes)Skin:No recommendation
Eyes:No recommendation
Wash skin:No recommendation
Remove:No recommendation
Change:No recommendation
Respirator Recommendations
NIOSH/OSHA
Up to 5 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.*
Up to 10 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.*
(APF = 10) Any supplied-air respirator*
Up to 25 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.*
Up to 50 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode*
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 500 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus
- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source:
- National Institute for Occupational Safety and Health (NIOSH) Education and Information Division