Fibrous glass dust
Synonyms & Trade Names
Fiber glas®, Fiberglass, Glass fibers, Glass wool [Note: Usually produced from borosilicate & low alkali silicate glasses.]Exposure Limits
NIOSH REL
TWA 3 fibers/cm3 (fibers ≤ 3.5 µm in diameter & ≥ 10 µm in length) TWA 5 mg/m3 (total)OSHA PEL
TWA 15 mg/m3 (total) TWA 5 mg/m3 (resp)Physical Description
Typically, glass filaments >3 µm in diameter or glass "wool" with diameters down to 0.05 µm & >1 µm in length.Molecular Weight
NABoiling Point
NAMelting Point
?Solubility
InsolubleVapor Pressure
0 mmHg (approx)Ionization Potential
NASpecific Gravity
2.5Flash Point
NAUpper Exposive Limit
NALower Explosive Limit
NAIncompatibilities & Reactivities
None reportedExposure Routes
inhalation, skin and/or eye contactSymptoms
irritation eyes, skin, nose, throat; dyspnea (breathing difficulty)Target Organs
Eyes, skin, respiratory systemPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:Daily
Remove:No recommendation
Change:Daily
Respirator Recommendations
NIOSH
Up to 5X REL:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.
Up to 10X REL:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 25X REL:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.
Up to 50X REL:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 1000X REL:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus
See also
INTRODUCTION- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source:
- National Institute for Occupational Safety and Health (NIOSH) Education and Information Division