Hydrogen cyanide
Synonyms & Trade Names
Formonitrile, Hydrocyanic acid, Prussic acidExposure Limits
NIOSH REL
ST 4.7 ppm (5 mg/m3) [skin]OSHA PEL
TWA 10 ppm (11 mg/m3) [skin] See Appendix GPhysical Description
Colorless or pale-blue liquid or gas (above 78°F) with a bitter, almond-like odor. [Note: Often used as a 96% solution in water.]Molecular Weight
27.0Boiling Point
78°F (96%)Freezing Point
7°F (96%)Solubility
MiscibleVapor Pressure
630 mmHgIonization Potential
13.60 eVSpecific Gravity
0.69Flash Point
0°F (96%)Upper Exposive Limit
40.0%Lower Explosive Limit
5.6%Incompatibilities & Reactivities
Amines, oxidizers, acids, sodium hydroxide, calcium hydroxide, sodium carbonate, caustics, ammonia [Note: Can polymerize at 122-140°F.]Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contactSymptoms
asphyxia; lassitude (weakness, exhaustion), headache, confusion; nausea, vomiting; increased rate and depth of respiration or respiration slow and gasping; thyroid, blood changesTarget Organs
central nervous system, cardiovascular system, thyroid, bloodPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet (flammable)
Change:No recommendation
Provide:Eyewash, Quick drench
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Water flush immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH
Up to 47 ppm:
(APF = 10) Any supplied-air respirator
Up to 50 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern
Any appropriate escape-type, self-contained breathing apparatus