Parathion
Synonyms & Trade Names
O,O-Diethyl-O(p-nitrophenyl) phosphorothioate, Diethyl parathion, Ethyl parathion, Parathion-ethylExposure Limits
NIOSH REL
TWA 0.05 mg/m3 [skin]OSHA PEL
TWA 0.1 mg/m3 [skin]Physical Description
Pale-yellow to dark-brown liquid with a garlic-like odor. [Note: A solid below 43°F. Pesticide that may be absorbed on a dry carrier.]Molecular Weight
291.3Boiling Point
707°FFreezing Point
43°FSolubility
0.001%Vapor Pressure
0.00004 mmHgIonization Potential
?Specific Gravity
1.27Flash Point
(oc) 392°FUpper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
Strong oxidizers, alkaline materialsExposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contactSymptoms
irritation eyes, skin, respiratory system; miosis; rhinorrhea (discharge of thin nasal mucus); headache; chest tightness, wheezing, laryngeal spasm, salivation, cyanosis; anorexia, nausea, vomiting, abdominal cramps, diarrhea; sweating; muscle fasciculation, lassitude (weakness, exhaustion), paralysis; dizziness, confusion, ataxia; convulsions, coma; low blood pressure; cardiac irregTarget Organs
Eyes, skin, respiratory system, central nervous system, cardiovascular system, blood cholinesterasePersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
Provide:Eyewash, Quick drench
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH
Up to 0.5 mg/m3:
(APF = 10) Any air-purifying half-mask respirator with organic vapor cartridge(s) in combination with an N95, R95, or P95 filter. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 1.25 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter.
Up to 2.5 mg/m3:
(APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 10 mg/m3:
(APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus
- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source:
- National Institute for Occupational Safety and Health (NIOSH) Education and Information Division