Pindone
Synonyms & Trade Names
tert-Butyl valone, 1,3-Dioxo-2-pivaloy-lindane, Pival®, Pivalyl, 2-Pivalyl-1,3-indandioneExposure Limits
NIOSH REL
TWA 0.1 mg/m3OSHA PEL
TWA 0.1 mg/m3Physical Description
Bright-yellow powder with almost no odor. [rodenticide]Molecular Weight
230.3Boiling Point
DecomposesMelting Point
230°FSolubility
(77°F): 0.002%Vapor Pressure
Very lowIonization Potential
?Specific Gravity
1.06Flash Point
?Upper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
None reportedExposure Routes
inhalation, ingestionSymptoms
epistaxis (nosebleed), excess bleeding from minor cuts, bruises; smoky urine, black tarry stools; abdominal, back painTarget Organs
Blood prothrombinPersonal Protection/Sanitation
(See protection codes)Skin:No recommendation
Eyes:No recommendation
Wash skin:No recommendation
Remove:No recommendation
Change:Daily
First Aid
(See procedures)Eye:Irrigate immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH/OSHA
Up to 0.5 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.
Up to 1 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 2.5 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.
Up to 5 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 100 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus