Strychnine
Synonyms & Trade Names
Nux vomica, StrynchnosExposure Limits
NIOSH REL
TWA 0.15 mg/m3OSHA PEL
TWA 0.15 mg/m3Physical Description
Colorless to white, odorless, crystalline solid. [pesticide]Molecular Weight
334.4Boiling Point
DecomposesMelting Point
514°FSolubility
0.02%Vapor Pressure
LowIonization Potential
?Specific Gravity
1.36Flash Point
?Upper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
Strong oxidizersExposure Routes
inhalation, ingestion, skin and/or eye contactSymptoms
Stiff neck, facial muscle; restlessness, anxiety, increased acuity of perception; increased reflex excitability; cyanosis; tetanic convulsions with opisthotonosTarget Organs
central nervous systemPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:No recommendation
Wash skin:When contaminated
Remove:No recommendation
Change:Daily
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH/OSHA
Up to 0.75 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.
Up to 1.5 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 3 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus
- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source:
- National Institute for Occupational Safety and Health (NIOSH) Education and Information Division