Uranium (soluble compounds, as U)
Synonyms & Trade Names
CAS No.
RTECS No.
DOT ID & Guide
Physical Description
Appearance and odor vary depending upon the specific soluble uranium compound.Molecular Weight
Properties vary depending upon the specific soluble uranium compound.Incompatibilities & Reactivities
Uranyl nitrate: combustibles Uranium hexafluoride: waterExposure Routes
inhalation, ingestion, skin and/or eye contactSymptoms
lacrimation (discharge of tears), conjunctivitis; short breath, cough, chest rales; nausea, vomiting; skin burns; red blood cell, casts in urine; proteinuria; high blood urea nitrogen; Potential for cancer is a result of alpha-emitting properties & radioactive decay products (e.g., radon). [potential occupational carcinogen]Target Organs
respiratory system, blood, liver, kidneys, lymphatic system, skin, bone marrowCancer Site
[lung cancer]Personal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated/Daily
Remove:When wet or contaminated
Change:Daily
Provide:Eyewash (UF6), Quick drench
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Water flush immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH
At concentrations above the NIOSH REL, or where there is no REL, at any detectable concentration:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape (Halides):
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted acid gas canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus
Escape (Non-halides):
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus