|
|
|||||||||
|
Persons using assistive technology might not be able to fully access information in this file. For assistance, please send e-mail to: mmwrq@cdc.gov. Type 508 Accommodation and the title of the report in the subject line of e-mail. Clinical Laboratory Measurements Traceable to the National Reference System for CholesterolAccurate laboratory measurements of blood lipids and lipoproteins (including total cholesterol {TC}, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and triglycerides) are important for diagnosing and managing coronary heart disease. The medical decision points established by the National Cholesterol Education Program (NCEP) were determined from an epidemiologic database standardized by the CDC reference method (RM) (1). The NCEP recommends that TC measurements made by all clinical laboratories in the United States be traceable (i.e., have a documented relation) to this accuracy base. The NCEP established specific national performance goals for the precision and accuracy of TC measurements. The goal for intralaboratory precision is less than or equal to 3% coefficient of variation, and the goal for bias is less than or equal to 3% from the true value. Laboratories can achieve the precision guidelines by establishing an active internal quality-control program. They can achieve the accuracy guidelines by improving the calibration of analytical systems and by verifying traceability to the National Reference System for Cholesterol (NRS/CHOL), of which the CDC RM is an integral part. To facilitate access to the NRS/CHOL and to provide an appropriate means for verifying traceability, in 1989, CDC established the Cholesterol Reference Method Laboratory Network (CRMLN). Clinical laboratories can evaluate their performance on fresh samples by completing a comparison with the reference method in a CRMLN laboratory. Participation is voluntary. The CRMLN documents successful comparisons with a "Certificate of Traceability," which is valid for 6 months. A national health objective for the year 2000 is to increase to at least 90% the proportion of clinical laboratories that meet the recommended accuracy standard for TC measurement (objective 15.17) (2). To verify the accuracy of their TC measurements, laboratories should contact a CRMLN laboratory (Table_1). Information about how clinical laboratories can participate in the program and the list of laboratories that have received Certificates of Traceability will be available beginning March 18, 1994, through the CDC Voice Information System, telephone (404) 332-2592. Reported by: Special Activities Br, Div of Environmental Health Laboratory Sciences, National Center for Environmental Health, CDC. References
Table_1 Note: To print large tables and graphs users may have to change their printer settings to landscape and use a small font size. TABLE 1. Laboratories participating in the Cholesterol Reference Method Laboratory Network -- United States and international UNITED STATES Pacific Biometrics Research Foundation State Laboratory of Hygiene 1100 Eastlake Avenue University of Wisconsin Seattle, WA 98109 Center for Health Sciences G. Russell Warnick, M.S. 465 Henry Mall (206) 233-9151 Phone Madison, WI 53706 (206) 233-0198 Fax David Hassemer, M.S. (608) 833-1770 (ext. 102) Phone INTERNATIONAL (608) 833-2803 Fax Rotterdam University Hospital Department of Clinical Chemistry Pennsylvania State Department of Health Lipid Reference Laboratory Bureau of Laboratories 3015 GD Rotterdam, THE NETHERLANDS Division of Chemistry and Toxicology Christa M. Boersma-Cobbaert, Ph.D. RO. Box 500 31-10-4633493 Phone Exton, PA 19341-0500 31-10-4367894 Fax Irene Daza (215) 363-8500 Phone Center for Adult Diseases, Osaka (215) 436-3346 Fax Department of Epidemiology and Mass Examination for CVD University of Minnesota 3 Nakamichi 1-chome Department of Laboratory Medicine and Pathology Higashinari-ku Box 198 UMHC Osaka 537, JAPAN 420 Delaware Street Masakazu Nakamura, Ph.D. Minneapolis, MN 55455-0392 81-6-972-1181 (ext. 2211) Phone John H. Eckfeldt, M.D. 81-6-972-7749 Fax (612) 626-3176 Phone (612) 625-6994 Fax Institute of Biochemistry Department of Pathological Biochemistry Northwest Lipid Research Laboratories Glasgow Royal Infirmary Core Laboratory 4th Floor Alexandra Parade 2121 N. 35th Street Glasgow G31 2ER, GREAT BRITAIN Seattle, WA 98103 Chris J. Packard, Ph.D. Santica Marcovina, Ph.D. 44-41-552-3535 Phone (206) 685-3331 Phone 44-41-553-2558 Fax (206) 685-3279 Fax Canadian Reference Foundation The Cleveland Clinic Foundation 307-2083 Alma Street Department of Biochemistry, L-11 Vancouver, British Columbia V6R 4N6, CANADA 9500 Euclid Avenue David W. Seccombe, M.D. Cleveland, OH 44195 (604) 222-1879 Phone Joan A. Waletzky (604) 222-0134 Fax (216) 444-8301 Phone (216) 444-4414 Fax UNDERGOING STANDARDIZATION Wadsworth Center for Laboratories and Research New York State Department of Health H.S. Raffaele Empire State Plaza Laboratorio Analisi Cliniche Albany, NY 12201 Via Olgettina 60 Robert Rej, Ph.D. 30132 Milano, ITALY (518) 473-0117 Phone Ferruccio Ceriotti, Ph.D. (518) 474-7992 Fax CERTIOTF%IMIHSRA.BITNET@VM.CNUCE.CNR.IT 011-39-2-2643-2315 (or 2313) Phone Washington University School of Medicine 011-39-2-2643-2640 Fax Lipid Research Center 4566 Scott Avenue Centre de Medicine Preventive St. Louis, MO 63110 Laboratorie de Biologie Clinique Thomas G. Cole, Ph.D. 2, avenue du Doyen J. Parisot (314) 362-3522 Phone 54500 Vandowuvre-les-Nancy, FRANCE (314) 362-7657 Fax Prof. Gerard Siest Josiane Steinmetz, Ph.D. USDA Human Nutrition Research Center on Aging 011-33-83-444415 Phone Tufts University 011-33-83-440361 Fax 711 Washington Street, Room 501 Boston, MA 02111 Judith R. McNamara (617) 556-3104 Phone (617) 556-3103 Fax Return to top. Disclaimer All MMWR HTML versions of articles are electronic conversions from ASCII text into HTML. This conversion may have resulted in character translation or format errors in the HTML version. Users should not rely on this HTML document, but are referred to the electronic PDF version and/or the original MMWR paper copy for the official text, figures, and tables. An original paper copy of this issue can be obtained from the Superintendent of Documents, U.S. Government Printing Office (GPO), Washington, DC 20402-9371; telephone: (202) 512-1800. Contact GPO for current prices. **Questions or messages regarding errors in formatting should be addressed to mmwrq@cdc.gov.Page converted: 09/19/98 |
|||||||||
This page last reviewed 5/2/01
|