n-Butyronitrile
Synonyms & Trade Names
Butanenitrile, Butyronitrile, 1-Cyanopropane, Propyl cyanide, n-Propyl cyanideExposure Limits
NIOSH REL
TWA 8 ppm (22 mg/m3)OSHA PEL
nonePhysical Description
Colorless liquid with a sharp, suffocating odor. [Note: Forms cyanide in the body.]Molecular Weight
69.1Boiling Point
244°FFreezing Point
-170°FSolubility
(77°F): 3%Vapor Pressure
14 mmHgIonization Potential
11.67 eVSpecific Gravity
0.81Flash Point
62°FUpper Exposive Limit
?Lower Explosive Limit
1.65%Incompatibilities & Reactivities
Strong oxidizers & reducing agents, strong acids & basesExposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contactSymptoms
irritation eyes, skin, respiratory system; headache, dizziness, lassitude (weakness, exhaustion), confusion, convulsions; dyspnea (breathing difficulty); abdominal pain, nausea, vomitingTarget Organs
Eyes, skin, respiratory system, central nervous system, cardiovascular systemPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet (flammable)
Change:No recommendation
Provide:Quick drench
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH
Up to 80 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)
(APF = 10) Any supplied-air respirator
Up to 200 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)
Up to 400 ppm:
(APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 1000 ppm:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus
- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source:
- National Institute for Occupational Safety and Health (NIOSH) Education and Information Division