Skip directly to search Skip directly to A to Z list Skip directly to navigation Skip directly to page options Skip directly to site content

Guideline for Disinfection and Sterilization in Healthcare Facilities (2008)

Chemical Disinfectants

Alcohol

Overview.

In the healthcare setting, “alcohol” refers to two water-soluble chemical compounds—ethyl alcohol and isopropyl alcohol—that have generally underrated germicidal characteristics 482. FDA has not cleared any liquid chemical sterilant or high-level disinfectant with alcohol as the main active ingredient. These alcohols are rapidly bactericidal rather than bacteriostatic against vegetative forms of bacteria; they also are tuberculocidal, fungicidal, and virucidal but do not destroy bacterial spores. Their cidal activity drops sharply when diluted below 50% concentration, and the optimum bactericidal concentration is 60%–90% solutions in water (volume/volume) 483, 484.

 Top of Page

Mode of Action.

The most feasible explanation for the antimicrobial action of alcohol is denaturation of proteins. This mechanism is supported by the observation that absolute ethyl alcohol, a dehydrating agent, is less bactericidal than mixtures of alcohol and water because proteins are denatured more quickly in the presence of water 484, 485. Protein denaturation also is consistent with observations that alcohol destroys the dehydrogenases of Escherichia coli 486, and that ethyl alcohol increases the lag phase of Enterobacter aerogenes 487 and that the lag phase effect could be reversed by adding certain amino acids. The bacteriostatic action was believed caused by inhibition of the production of metabolites essential for rapid cell division.

 Top of Page

Microbicidal Activity.

Methyl alcohol (methanol) has the weakest bactericidal action of the alcohols and thus seldom is used in healthcare 488. The bactericidal activity of various concentrations of ethyl alcohol (ethanol) was examined against a variety of microorganisms in exposure periods ranging from 10 seconds to 1 hour 483. Pseudomonas aeruginosa was killed in 10 seconds by all concentrations of ethanol from 30% to 100% (v/v), and Serratia marcescens, E, coli and Salmonella typhosa were killed in 10 seconds by all concentrations of ethanol from 40% to 100%. The gram-positive organisms Staphylococcus aureus and Streptococcus pyogenes were slightly more resistant, being killed in 10 seconds by ethyl alcohol concentrations of 60%–95%. Isopropyl alcohol (isopropanol) was slightly more bactericidal than ethyl alcohol for E. coli and S. aureus 489.

 Top of Page

Ethyl alcohol, at concentrations of 60%–80%, is a potent virucidal agent inactivating all of the lipophilic viruses (e.g., herpes, vaccinia, and influenza virus) and many hydrophilic viruses (e.g., adenovirus, enterovirus, rhinovirus, and rotaviruses but not hepatitis A virus (HAV) 58 or poliovirus) 49. Isopropyl alcohol is not active against the nonlipid enteroviruses but is fully active against the lipid viruses 72. Studies also have demonstrated the ability of ethyl and isopropyl alcohol to inactivate the hepatitis B virus(HBV) 224, 225 and the herpes virus, 490 and ethyl alcohol to inactivate human immunodeficiency virus (HIV) 227, rotavirus, echovirus, and astrovirus 491.

 Top of Page

In tests of the effect of ethyl alcohol against M. tuberculosis, 95% ethanol killed the tubercle bacilli in sputum or water suspension within 15 seconds 492. In 1964, Spaulding stated that alcohols were the germicide of choice for tuberculocidal activity, and they should be the standard by which all other tuberculocides are compared. For example, he compared the tuberculocidal activity of iodophor (450 ppm), a substituted phenol (3%), and isopropanol (70%/volume) using the mucin-loop test (106 M. tuberculosis per loop) and determined the contact times needed for complete destruction were 120–180 minutes, 45–60 minutes, and 5 minutes, respectively. The mucin-loop test is a severe test developed to produce long survival times. Thus, these figures should not be extrapolated to the exposure times needed when these germicides are used on medical or surgical material 482.

Ethyl alcohol (70%) was the most effective concentration for killing the tissue phase of Cryptococcus neoformans, Blastomyces dermatitidis, Coccidioides immitis, and Histoplasma capsulatum and the culture phases of the latter three organisms aerosolized onto various surfaces. The culture phase was more resistant to the action of ethyl alcohol and required about 20 minutes to disinfect the contaminated surface, compared with <1 minute for the tissue phase 493, 494.

Isopropyl alcohol (20%) is effective in killing the cysts of Acanthamoeba culbertsoni (560) as are chlorhexidine, hydrogen peroxide, and thimerosal 496.

 Top of Page

Uses.

Alcohols are not recommended for sterilizing medical and surgical materials principally because they lack sporicidal action and they cannot penetrate protein-rich materials. Fatal postoperative wound infections with Clostridium have occurred when alcohols were used to sterilize surgical instruments contaminated with bacterial spores 497. Alcohols have been used effectively to disinfect oral and rectal thermometers498, 499, hospital pagers 500, scissors 501, and stethoscopes 502. Alcohols have been used to disinfect fiberoptic endoscopes 503, 504 but failure of this disinfectant have lead to infection 280, 505. Alcohol towelettes have been used for years to disinfect small surfaces such as rubber stoppers of multiple-dose medication vials or vaccine bottles. Furthermore, alcohol occasionally is used to disinfect external surfaces of equipment (e.g., stethoscopes, ventilators, manual ventilation bags) 506, CPR manikins 507, ultrasound instruments 508 or medication preparation areas. Two studies demonstrated the effectiveness of 70% isopropyl alcohol to disinfect reusable transducer heads in a controlled environment 509, 510. In contrast, three bloodstream infection outbreaks have been described when alcohol was used to disinfect transducer heads in an intensive-care setting 511.

 Top of Page

The documented shortcomings of alcohols on equipment are that they damage the shellac mountings of lensed instruments, tend to swell and harden rubber and certain plastic tubing after prolonged and repeated use, bleach rubber and plastic tiles 482 and damage tonometer tips (by deterioration of the glue) after the equivalent of 1 working year of routine use 512. Tonometer biprisms soaked in alcohol for 4 days developed rough front surfaces that potentially could cause corneal damage; this appeared to be caused by weakening of the cementing substances used to fabricate the biprisms 513. Corneal opacification has been reported when tonometer tips were swabbed with alcohol immediately before measurement of intraocular pressure 514. Alcohols are flammable and consequently must be stored in a cool, well-ventilated area. They also evaporate rapidly, making extended exposure time difficult to achieve unless the items are immersed.

 Top of Page

Chlorine and Chlorine Compounds

Overview.

Hypochlorites, the most widely used of the chlorine disinfectants, are available as liquid (e.g., sodium hypochlorite) or solid (e.g., calcium hypochlorite). The most prevalent chlorine products in the United States are aqueous solutions of 5.25%–6.15% sodium hypochlorite (see glossary), usually called household bleach. They have a broad spectrum of antimicrobial activity, do not leave toxic residues, are unaffected by water hardness, are inexpensive and fast acting 328, remove dried or fixed organisms and biofilms from surfaces465, and have a low incidence of serious toxicity 515-517. Sodium hypochlorite at the concentration used in household bleach (5.25-6.15%) can produce ocular irritation or oropharyngeal, esophageal, and gastric burns 318, 518-522. Other disadvantages of hypochlorites include corrosiveness to metals in high concentrations (>500 ppm), inactivation by organic matter, discoloring or “bleaching” of fabrics, release of toxic chlorine gas when mixed with ammonia or acid (e.g., household cleaning agents) 523-525, and relative stability 327. The microbicidal activity of chlorine is attributed largely to undissociated hypochlorous acid (HOCl). The dissociation of HOCI to the less microbicidal form (hypochlorite ion OCl) depends on pH. The disinfecting efficacy of chlorine decreases with an increase in pH that parallels the conversion of undissociated HOCI to OCl 329, 526. A potential hazard is production of the carcinogen bis(chloromethyl) ether when hypochlorite solutions contact formaldehyde 527 and the production of the animal carcinogen trihalomethane when hot water is hyperchlorinated 528. After reviewing environmental fate and ecologic data, EPA has determined the currently registered uses of hypochlorites will not result in unreasonable adverse effects to the environment 529.

 Top of Page

Alternative compounds that release chlorine and are used in the health-care setting include demand-release chlorine dioxide, sodium dichloroisocyanurate, and chloramine-T. The advantage of these compounds over the hypochlorites is that they retain chlorine longer and so exert a more prolonged bactericidal effect. Sodium dichloroisocyanurate tablets are stable, and for two reasons, the microbicidal activity of solutions prepared from sodium dichloroisocyanurate tablets might be greater than that of sodium hypochlorite solutions containing the same total available chlorine. First, with sodium dichloroisocyanurate, only 50% of the total available chlorine is free (HOCl and OCl), whereas the remainder is combined (monochloroisocyanurate or dichloroisocyanurate), and as free available chlorine is used up, the latter is released to restore the equilibrium. Second, solutions of sodium dichloroisocyanurate are acidic, whereas sodium hypochlorite solutions are alkaline, and the more microbicidal type of chlorine (HOCl) is believed to predominate 530-533. Chlorine dioxide-based disinfectants are prepared fresh as required by mixing the two components (base solution [citric acid with preservatives and corrosion inhibitors] and the activator solution [sodium chlorite]). In vitro suspension tests showed that solutions containing about 140 ppm chlorine dioxide achieved a reduction factor exceeding 106 of S. aureus in 1 minute and of Bacillus atrophaeus spores in 2.5 minutes in the presence of 3 g/L bovine albumin. The potential for damaging equipment requires consideration because long-term use can damage the outer plastic coat of the insertion tube 534. In another study, chlorine dioxide solutions at either 600 ppm or 30 ppm killed Mycobacterium avium-intracellulare within 60 seconds after contact but contamination by organic material significantly affected the microbicidal properties535.

 Top of Page

The microbicidal activity of a new disinfectant, “superoxidized water,” has been examined The concept of electrolyzing saline to create a disinfectant or antiseptics is appealing because the basic materials of saline and electricity are inexpensive and the end product (i.e., water) does not damage the environment. The main products of this water are hypochlorous acid (e.g., at a concentration of about 144 mg/L) and chlorine. As with any germicide, the antimicrobial activity of superoxidized water is strongly affected by the concentration of the active ingredient (available free chlorine) 536. One manufacturer generates the disinfectant at the point of use by passing a saline solution over coated titanium electrodes at 9 amps. The product generated has a pH of 5.0–6.5 and an oxidation-reduction potential (redox) of >950 mV. Although superoxidized water is intended to be generated fresh at the point of use, when tested under clean conditions the disinfectant was effective within 5 minutes when 48 hours old 537. Unfortunately, the equipment required to produce the product can be expensive because parameters such as pH, current, and redox potential must be closely monitored. The solution is nontoxic to biologic tissues. Although the United Kingdom manufacturer claims the solution is noncorrosive and nondamaging to endoscopes and processing equipment, one flexible endoscope manufacturer (Olympus Key-Med, United Kingdom) has voided the warranty on the endoscopes if superoxidized water is used to disinfect them 538. As with any germicide formulation, the user should check with the device manufacturer for compatibility with the germicide. Additional studies are needed to determine whether this solution could be used as an alternative to other disinfectants or antiseptics for hand washing, skin antisepsis, room cleaning, or equipment disinfection (e.g., endoscopes, dialyzers) 400, 539, 540. In October 2002, the FDA cleared superoxidized water as a high-level disinfectant (FDA, personal communication, September 18, 2002).

 Top of Page

Mode of Action.

The exact mechanism by which free chlorine destroys microorganisms has not been elucidated. Inactivation by chlorine can result from a number of factors: oxidation of sulfhydryl enzymes and amino acids; ring chlorination of amino acids; loss of intracellular contents; decreased uptake of nutrients; inhibition of protein synthesis; decreased oxygen uptake; oxidation of respiratory components; decreased adenosine triphosphate production; breaks in DNA; and depressed DNA synthesis 329, 347. The actual microbicidal mechanism of chlorine might involve a combination of these factors or the effect of chlorine on critical sites 347.

 Top of Page

Microbicidal Activity.

Low concentrations of free available chlorine (e.g., HOCl, OCl, and elemental chlorine-Cl2) have a biocidal effect on mycoplasma (25 ppm) and vegetative bacteria (<5 ppm) in seconds in the absence of an organic load 329, 418. Higher concentrations (1,000 ppm) of chlorine are required to kill M. tuberculosis using the Association of Official Analytical Chemists (AOAC) tuberculocidal test 73. A concentration of 100 ppm will kill ≥99.9% of B. atrophaeus spores within 5 minutes 541, 542 and destroy mycotic agents in <1 hour 329. Acidified bleach and regular bleach (5,000 ppm chlorine) can inactivate 106 Clostridium difficile spores in ≤10 minutes 262. One study reported that 25 different viruses were inactivated in 10 minutes with 200 ppm available chlorine 72. Several studies have demonstrated the effectiveness of diluted sodium hypochlorite and other disinfectants to inactivate HIV 61. Chlorine (500 ppm) showed inhibition of Candida after 30 seconds of exposure 54. In experiments using the AOAC Use-Dilution Method, 100 ppm of free chlorine killed 106–107 S. aureus, Salmonella choleraesuis, and P. aeruginosa in <10 minutes 327. Because household bleach contains 5.25%–6.15% sodium hypochlorite, or 52,500–61,500 ppm available chlorine, a 1:1,000 dilution provides about 53–62 ppm available chlorine, and a 1:10 dilution of household bleach provides about 5250–6150 ppm.

 Top of Page

Data are available for chlorine dioxide that support manufacturers’ bactericidal, fungicidal, sporicidal, tuberculocidal, and virucidal label claims 543-546. A chlorine dioxide generator has been shown effective for decontaminating flexible endoscopes 534 but it is not currently FDA-cleared for use as a high-level disinfectant 85. Chlorine dioxide can be produced by mixing solutions, such as a solution of chlorine with a solution of sodium chlorite 329. In 1986, a chlorine dioxide product was voluntarily removed from the market when its use caused leakage of cellulose-based dialyzer membranes, which allowed bacteria to migrate from the dialysis fluid side of the dialyzer to the blood side 547.

 Sodium dichloroisocyanurate at 2,500 ppm available chlorine is effective against bacteria in the presence of up to 20% plasma, compared with 10% plasma for sodium hypochlorite at 2,500 ppm 548.

 Top of Page

“Superoxidized water” has been tested against bacteria, mycobacteria, viruses, fungi, and spores 537, 539, 549. Freshly generated superoxidized water is rapidly effective (<2 minutes) in achieving a 5-log10 reduction of pathogenic microorganisms (i.e., M. tuberculosis, M. chelonae, poliovirus, HIV, multidrug-resistant S. aureus, E. coli, Candida albicans, Enterococcus faecalis, P. aeruginosa) in the absence of organic loading. However, the biocidal activity of this disinfectant decreased substantially in the presence of organic material (e.g., 5% horse serum) 537, 549, 550. No bacteria or viruses were detected on artificially contaminated endoscopes after a 5-minute exposure to superoxidized water 551 and HBV-DNA was not detected from any endoscope experimentally contaminated with HBV-positive mixed sera after a disinfectant exposure time of 7 minutes552.

 Top of Page

Uses.

Hypochlorites are widely used in healthcare facilities in a variety of settings. 328 Inorganic chlorine solution is used for disinfecting tonometer heads 188 and for spot-disinfection of countertops and floors. A 1:10–1:100 dilution of 5.25%–6.15% sodium hypochlorite (i.e., household bleach) 22, 228, 553, 554 or an EPA-registered tuberculocidal disinfectant 17has been recommended for decontaminating blood spills. For small spills of blood (i.e., drops of blood) on noncritical surfaces, the area can be disinfected with a 1:100 dilution of 5.25%-6.15% sodium hypochlorite or an EPA-registered tuberculocidal disinfectant. Because hypochlorites and other germicides are substantially inactivated in the presence of blood 63, 548, 555, 556, large spills of blood require that the surface be cleaned before an EPA-registered disinfectant or a 1:10 (final concentration) solution of household bleach is applied 557. If a sharps injury is possible, the surface initially should be decontaminated 69, 318, then cleaned and disinfected (1:10 final concentration) 63. Extreme care always should be taken to prevent percutaneous injury. At least 500 ppm available chlorine for 10 minutes is recommended for decontaminating CPR training manikins 558. Full-strength bleach has been recommended for self-disinfection of needles and syringes used for illicit-drug injection when needle-exchange programs are not available. The difference in the recommended concentrations of bleach reflects the difficulty of cleaning the interior of needles and syringes and the use of needles and syringes for parenteral injection 559. Clinicians should not alter their use of chlorine on environmental surfaces on the basis of testing methodologies that do not simulate actual disinfection practices 560, 561. Other uses in healthcare include as an irrigating agent in endodontic treatment 562 and as a disinfectant for manikins, laundry, dental appliances, hydrotherapy tanks 23, 41, regulated medical waste before disposal 328, and the water distribution system in hemodialysis centers and hemodialysis machines 563.

 Top of Page

Chlorine long has been used as the disinfectant in water treatment. Hyperchlorination of a Legionella-contaminated hospital water system 23 resulted in a dramatic decrease (from 30% to 1.5%) in the isolation of L. pneumophila from water outlets and a cessation of healthcare-associated Legionnaires’ disease in an affected unit 528, 564. Water disinfection with monochloramine by municipal water-treatment plants substantially reduced the risk for healthcare–associated Legionnaires disease 565, 566. Chlorine dioxide also has been used to control Legionella in a hospital water supply. 567 Chloramine T 568 and hypochlorites 41 have been used to disinfect hydrotherapy equipment.

  Hypochlorite solutions in tap water at a pH >8 stored at room temperature (23°C) in closed, opaque plastic containers can lose up to 40%–50% of their free available chlorine level over 1 month. Thus, if a user wished to have a solution containing 500 ppm of available chlorine at day 30, he or she should prepare a solution containing 1,000 ppm of chlorine at time 0. Sodium hypochlorite solution does not decompose after 30 days when stored in a closed brown bottle 327.

The use of powders, composed of a mixture of a chlorine-releasing agent with highly absorbent resin, for disinfecting spills of body fluids has been evaluated by laboratory tests and hospital ward trials. The inclusion of acrylic resin particles in formulations markedly increases the volume of fluid that can be soaked up because the resin can absorb 200–300 times its own weight of fluid, depending on the fluid consistency. When experimental formulations containing 1%, 5%, and 10% available chlorine were evaluated by a standardized surface test, those containing 10% demonstrated bactericidal activity. One problem with chlorine-releasing granules is that they can generate chlorine fumes when applied to urine 569.

 Top of Page

Formaldehyde

Overview.

Formaldehyde is used as a disinfectant and sterilant in both its liquid and gaseous states. Liquid formaldehyde will be considered briefly in this section, and the gaseous form is reviewed elsewhere 570. Formaldehyde is sold and used principally as a water-based solution called formalin, which is 37% formaldehyde by weight. The aqueous solution is a bactericide, tuberculocide, fungicide, virucide and sporicide 72, 82, 571-573. OSHA indicated that formaldehyde should be handled in the workplace as a potential carcinogen and set an employee exposure standard for formaldehyde that limits an 8-hour time-weighted average exposure concentration of 0.75 ppm 574, 575. The standard includes a second permissible exposure limit in the form of a short-term exposure limit (STEL) of 2 ppm that is the maximum exposure allowed during a 15-minute period 576. Ingestion of formaldehyde can be fatal, and long-term exposure to low levels in the air or on the skin can cause asthma-like respiratory problems and skin irritation, such as dermatitis and itching. For these reasons, employees should have limited direct contact with formaldehyde, and these considerations limit its role in sterilization and disinfection processes. Key provisions of the OSHA standard that protects workers from exposure to formaldehyde appear in Title 29 of the Code of Federal Regulations (CFR) Part 1910.1048 (and equivalent regulations in states with OSHA-approved state plans) 577.

 Top of Page

Mode of Action.

Formaldehyde inactivates microorganisms by alkylating the amino and sulfhydral groups of proteins and ring nitrogen atoms of purine bases 376.

 Top of Page

Microbicidal Activity.

Varying concentrations of aqueous formaldehyde solutions destroy a wide range of microorganisms. Inactivation of poliovirus in 10 minutes required an 8% concentration of formalin, but all other viruses tested were inactivated with 2% formalin 72. Four percent formaldehyde is a tuberculocidal agent, inactivating 104 M. tuberculosis in 2 minutes 82, and 2.5% formaldehyde inactivated about 107 Salmonella Typhi in 10 minutes in the presence of organic matter 572. The sporicidal action of formaldehyde was slower than that of glutaraldehyde in comparative tests with 4% aqueous formaldehyde and 2% glutaraldehyde against the spores of B. anthracis 82. The formaldehyde solution required 2 hours of contact to achieve an inactivation factor of 104, whereas glutaraldehyde required only 15 minutes.

 Top of Page

Uses.

Although formaldehyde-alcohol is a chemical sterilant and formaldehyde is a high-level disinfectant, the health-care uses of formaldehyde are limited by its irritating fumes and its pungent odor even at very low levels (<1 ppm). For these reasons and others—such as its role as a suspected human carcinogen linked to nasal cancer and lung cancer 578, this germicide is excluded from Table 1. When it is used, , direct exposure to employees generally is limited; however, excessive exposures to formaldehyde have been documented for employees of renal transplant units 574, 579, and students in a gross anatomy laboratory 580. Formaldehyde is used in the health-care setting to prepare viral vaccines (e.g., poliovirus and influenza); as an embalming agent; and to preserve anatomic specimens; and historically has been used to sterilize surgical instruments, especially when mixed with ethanol. A 1997 survey found that formaldehyde was used for reprocessing hemodialyzers by 34% of U.S. hemodialysis centers—a 60% decrease from 1983 249, 581. If used at room temperature, a concentration of 4% with a minimum exposure of 24 hours is required to disinfect disposable hemodialyzers reused on the same patient 582, 583. Aqueous formaldehyde solutions (1%–2%) also have been used to disinfect the internal fluid pathways of dialysis machines 583. To minimize a potential health hazard to dialysis patients, the dialysis equipment must be thoroughly rinsed and tested for residual formaldehyde before use.

Paraformaldehyde, a solid polymer of formaldehyde, can be vaporized by heat for the gaseous decontamination of laminar flow biologic safety cabinets when maintenance work or filter changes require access to the sealed portion of the cabinet.

 Top of Page

Glutaraldehyde

Overview.

Glutaraldehyde is a saturated dialdehyde that has gained wide acceptance as a high-level disinfectant and chemical sterilant 107. Aqueous solutions of glutaraldehyde are acidic and generally in this state are not sporicidal. Only when the solution is “activated” (made alkaline) by use of alkalinating agents to pH 7.5–8.5 does the solution become sporicidal. Once activated, these solutions have a shelf-life of minimally 14 days because of the polymerization of the glutaraldehyde molecules at alkaline pH levels. This polymerization blocks the active sites (aldehyde groups) of the glutaraldehyde molecules that are responsible for its biocidal activity.

 Top of Page

Novel glutaraldehyde formulations (e.g., glutaraldehyde-phenol-sodium phenate, potentiated acid glutaraldehyde, stabilized alkaline glutaraldehyde) produced in the past 30 years have overcome the problem of rapid loss of activity (e.g., use-life 28–30 days) while generally maintaining excellent microbicidal activity 584-588. However, antimicrobial activity depends not only on age but also on use conditions, such as dilution and organic stress. Manufacturers’ literature for these preparations suggests the neutral or alkaline glutaraldehydes possess microbicidal and anticorrosion properties superior to those of acid glutaraldehydes, and a few published reports substantiate these claims 542, 589, 590. However, two studies found no difference in the microbicidal activity of alkaline and acid glutaraldehydes 73, 591. The use of glutaraldehyde-based solutions in health-care facilities is widespread because of their advantages, including excellent biocidal properties; activity in the presence of organic matter (20% bovine serum); and noncorrosive action to endoscopic equipment, thermometers, rubber, or plastic equipment (Tables 4 and 5).

 Top of Page

Mode of Action.

The biocidal activity of glutaraldehyde results from its alkylation of sulfhydryl, hydroxyl, carboxyl, and amino groups of microorganisms, which alters RNA, DNA, and protein synthesis. The mechanism of action of glutaraldehydes are reviewed extensively elsewhere 592, 593.

 Top of Page

Microbicidal Activity.

The in vitro inactivation of microorganisms by glutaraldehydes has been extensively investigated and reviewed 592, 593. Several investigators showed that ≥2% aqueous solutions of glutaraldehyde, buffered to pH 7.5–8.5 with sodium bicarbonate effectively killed vegetative bacteria in <2 minutes; M. tuberculosis, fungi, and viruses in <10 minutes; and spores of Bacillus and Clostridium species in 3 hours 542, 592-597. Spores of C. difficile are more rapidly killed by 2% glutaraldehyde than are spores of other species of Clostridium and Bacillus 79, 265, 266. Microorganisms with substantial resistance to glutaraldehyde have been reported, including some mycobacteria (M. chelonae, Mycobacterium avium-intracellulare, M. xenopi) 598-601, Methylobacterium mesophilicum 602, Trichosporon, fungal ascospores (e.g., Microascus cinereus, Cheatomium globosum), and Cryptosporidium271, 603. M. chelonae persisted in a 0.2% glutaraldehyde solution used to store porcine prosthetic heart valves 604.

 Top of Page

Two percent alkaline glutaraldehyde solution inactivated 105 M. tuberculosis cells on the surface of penicylinders within 5 minutes at 18°C 589. However, subsequent studies82 questioned the mycobactericidal prowess of glutaraldehydes. Two percent alkaline glutaraldehyde has slow action (20 to >30 minutes) against M. tuberculosis and compares unfavorably with alcohols, formaldehydes, iodine, and phenol 82. Suspensions of M. avium, M. intracellulare, and M. gordonae were more resistant to inactivation by a 2% alkaline glutaraldehyde (estimated time to complete inactivation: ~60 minutes) than were virulent M. tuberculosis (estimated time to complete inactivation ~25 minutes) 605. The rate of kill was directly proportional to the temperature, and a standardized suspension of M. tuberculosis could not be sterilized within 10 minutes 84. An FDA-cleared chemical sterilant containing 2.5% glutaraldehyde uses increased temperature (35°C) to reduce the time required to achieve high-level disinfection (5 minutes) 85, 606, but its use is limited to automatic endoscope reprocessors equipped with a heater. In another study employing membrane filters for measurement of mycobactericidal activity of 2% alkaline glutaraldehyde, complete inactivation was achieved within 20 minutes at 20°C when the test inoculum was 106 M. tuberculosis per membrane 81. Several investigators 55, 57, 73, 76, 80, 81, 84, 605 have demonstrated that glutaraldehyde solutions inactivate 2.4 to >5.0 log10 of M. tuberculosis in 10 minutes (including multidrug-resistant M. tuberculosis) and 4.0–6.4 log10 of M. tuberculosis in 20 minutes. On the basis of these data and other studies, 20 minutes at room temperature is considered the minimum exposure time needed to reliably kill Mycobacteria and other vegetative bacteria with ≥2% glutaraldehyde 17, 19, 27, 57, 83, 94, 108, 111, 117-121, 607.

 Top of Page

Glutaraldehyde is commonly diluted during use, and studies showed a glutaraldehyde concentration decline after a few days of use in an automatic endoscope washer 608, 609. The decline occurs because instruments are not thoroughly dried and water is carried in with the instrument, which increases the solution’s volume and dilutes its effective concentration 610. This emphasizes the need to ensure that semicritical equipment is disinfected with an acceptable concentration of glutaraldehyde. Data suggest that 1.0%–1.5% glutaraldehyde is the minimum effective concentration for >2% glutaraldehyde solutions when used as a high-level disinfectant 76, 589, 590, 609. Chemical test strips or liquid chemical monitors 610, 611 are available for determining whether an effective concentration of glutaraldehyde is present despite repeated use and dilution. The frequency of testing should be based on how frequently the solutions are used (e.g., used daily, test daily; used weekly, test before use; used 30 times per day, test each 10th use), but the strips should not be used to extend the use life beyond the expiration date. Data suggest the chemicals in the test strip deteriorate with time 612 and a manufacturer’s expiration date should be placed on the bottles. The bottle of test strips should be dated when opened and used for the period of time indicated on the bottle (e.g., 120 days). The results of test strip monitoring should be documented. The glutaraldehyde test kits have been preliminarily evaluated for accuracy and range 612 but the reliability has been questioned 613. To ensure the presence of minimum effective concentration of the high-level disinfectant, manufacturers of some chemical test strips recommend the use of quality-control procedures to ensure the strips perform properly. If the manufacturer of the chemical test strip recommends a quality-control procedure, users should comply with the manufacturer’s recommendations. The concentration should be considered unacceptable or unsafe when the test indicates a dilution below the product’s minimum effective concentration (MEC) (generally to ≤1.0%–1.5% glutaraldehyde) by the indicator not changing color.

 Top of Page

A 2.0% glutaraldehyde–7.05% phenol–1.20% sodium phenate product that contained 0.125% glutaraldehyde–0.44% phenol–0.075% sodium phenate when diluted 1:16 is not recommended as a high-level disinfectant because it lacks bactericidal activity in the presence of organic matter and lacks tuberculocidal, fungicidal, virucidal, and sporicidal activity 49, 55, 56, 71, 73-79, 614. In December 1991, EPA issued an order to stop the sale of all batches of this product because of efficacy data showing the product is not effective against spores and possibly other microorganisms or inanimate objects as claimed on the label 615. FDA has cleared a glutaraldehyde–phenol/phenate concentrate as a high-level disinfectant that contains 1.12% glutaraldehyde with 1.93% phenol/phenate at its use concentration. Other FDA cleared glutaraldehyde sterilants that contain 2.4%–3.4% glutaraldehyde are used undiluted 606.

 Top of Page

Uses.

Glutaraldehyde is used most commonly as a high-level disinfectant for medical equipment such as endoscopes 69, 107, 504, spirometry tubing, dialyzers 616, transducers, anesthesia and respiratory therapy equipment 617, hemodialysis proportioning and dialysate delivery systems 249, 618, and reuse of laparoscopic disposable plastic trocars 619. Glutaraldehyde is noncorrosive to metal and does not damage lensed instruments, rubber. or plastics. Glutaraldehyde should not be used for cleaning noncritical surfaces because it is too toxic and expensive.

Colitis believed caused by glutaraldehyde exposure from residual disinfecting solution in endoscope solution channels has been reported and is preventable by careful endoscope rinsing 318, 620-630. One study found that residual glutaraldehyde levels were higher and more variable after manual disinfection (<0.2 mg/L to 159.5 mg/L) than after automatic disinfection (0.2–6.3 mg/L)631. Similarly, keratopathy and corneal decompensation were caused by ophthalmic instruments that were inadequately rinsed after soaking in 2% glutaraldehyde 632, 633.

 Healthcare personnel can be exposed to elevated levels of glutaraldehyde vapor when equipment is processed in poorly ventilated rooms, when spills occur, when glutaraldehyde solutions are activated or changed,634, or when open immersion baths are used. Acute or chronic exposure can result in skin irritation or dermatitis, mucous membrane irritation (eye, nose, mouth), or pulmonary symptoms 318, 635-639. Epistaxis, allergic contact dermatitis, asthma, and rhinitis also have been reported in healthcare workers exposed to glutaraldehyde 636, 640-647.

 Top of Page

Glutaraldehyde exposure should be monitored to ensure a safe work environment. Testing can be done by four techniques: a silica gel tube/gas chromatography with a flame ionization detector, dinitrophenylhydrazine (DNPH)-impregnated filter cassette/high-performance liquid chromatography (HPLC) with an ultraviolet (UV) detector, a passive badge/HPLC, or a handheld glutaraldehyde air monitor 648. The silica gel tube and the DNPH-impregnated cassette are suitable for monitoring the 0.05 ppm ceiling limit. The passive badge, with a 0.02 ppm limit of detection, is considered marginal at the Americal Council of Governmental Industrial Hygienists (ACGIH) ceiling level. The ceiling level is considered too close to the glutaraldehyde meter’s 0.03 ppm limit of detection to provide confidence in the readings 648. ACGIH does not require a specific monitoring schedule for glutaraldehyde; however, a monitoring schedule is needed to ensure the level is less than the ceiling limit. For example, monitoring should be done initially to determine glutaraldehyde levels, after procedural or equipment changes, and in response to worker complaints 649. In the absence of an OSHA permissible exposure limit, if the glutaraldehyde level is higher than the ACGIH ceiling limit of 0.05 ppm, corrective action and repeat monitoring would be prudent 649.

Engineering and work-practice controls that can be used to resolve these problems include ducted exhaust hoods, air systems that provide 7–15 air exchanges per hour, ductless fume hoods with absorbents for the glutaraldehyde vapor, tight-fitting lids on immersion baths, personal protection (e.g., nitrile or butyl rubber gloves but not natural latex gloves, goggles) to minimize skin or mucous membrane contact, and automated endoscope processors 7, 650. If engineering controls fail to maintain levels below the ceiling limit, institutions can consider the use of respirators (e.g., a half-face respirator with organic vapor cartridge 640 or a type “C” supplied air respirator with a full facepiece operated in a positive pressure mode) 651. In general, engineering controls are preferred over work-practice and administrative controls because they do not require active participation by the health-care worker. Even though enforcement of the OSHA ceiling limit was suspended in 1993 by the U.S. Court of Appeals 577, limiting employee exposure to 0.05 ppm (according to ACGIH) is prudent because, at this level, glutaraldehyde can irritate the eyes, throat, and nose 318, 577, 639, 652. If glutaraldehyde disposal through the sanitary sewer system is restricted, sodium bisulfate can be used to neutralize the glutaraldehyde and make it safe for disposal.

 Top of Page

Hydrogen Peroxide

Overview.

The literature contains several accounts of the properties, germicidal effectiveness, and potential uses for stabilized hydrogen peroxide in the health-care setting. Published reports ascribe good germicidal activity to hydrogen peroxide and attest to its bactericidal, virucidal, sporicidal, and fungicidal properties 653-655. (Tables 4 and 5) The FDA website lists cleared liquid chemical sterilants and high-level disinfectants containing hydrogen peroxide and their cleared contact conditions.

 Top of Page

Mode of Action.

Hydrogen peroxide works by producing destructive hydroxyl free radicals that can attack membrane lipids, DNA, and other essential cell components. Catalase, produced by aerobic organisms and facultative anaerobes that possess cytochrome systems, can protect cells from metabolically produced hydrogen peroxide by degrading hydrogen peroxide to water and oxygen. This defense is overwhelmed by the concentrations used for disinfection 653, 654.

 Top of Page

Microbicidal Activity.

Hydrogen peroxide is active against a wide range of microorganisms, including bacteria, yeasts, fungi, viruses, and spores 78, 654. A 0.5% accelerated hydrogen peroxide demonstrated bactericidal and virucidal activity in 1 minute and mycobactericidal and fungicidal activity in 5 minutes 656. Bactericidal effectiveness and stability of hydrogen peroxide in urine has been demonstrated against a variety of health-care–associated pathogens; organisms with high cellular catalase activity (e.g., S. aureus, S. marcescens, and Proteus mirabilis) required 30–60 minutes of exposure to 0.6% hydrogen peroxide for a 108 reduction in cell counts, whereas organisms with lower catalase activity (e.g., E. coli, Streptococcus species, and Pseudomonas species) required only 15 minutes’ exposure 657. In an investigation of 3%, 10%, and 15% hydrogen peroxide for reducing spacecraft bacterial populations, a complete kill of 106 spores (i.e., Bacillus species) occurred with a 10% concentration and a 60-minute exposure time. A 3% concentration for 150 minutes killed 106 spores in six of seven exposure trials 658. A 10% hydrogen peroxide solution resulted in a 103 decrease in B. atrophaeus spores, and a ≥105 decrease when tested against 13 other pathogens in 30 minutes at 20°C 659, 660. A 3.0% hydrogen peroxide solution was ineffective against VRE after 3 and 10 minutes exposure times 661 and caused only a 2-log10 reduction in the number of Acanthamoeba cysts in approximately 2 hours 662. A 7% stabilized hydrogen peroxide proved to be sporicidal (6 hours of exposure), mycobactericidal (20 minutes), fungicidal (5 minutes) at full strength, virucidal (5 minutes) and bactericidal (3 minutes) at a 1:16 dilution when a quantitative carrier test was used 655. The 7% solution of hydrogen peroxide, tested after 14 days of stress (in the form of germ-loaded carriers and respiratory therapy equipment), was sporicidal (>7 log10 reduction in 6 hours), mycobactericidal (>6.5 log10 reduction in 25 minutes), fungicidal (>5 log10 reduction in 20 minutes), bactericidal (>6 log10 reduction in 5 minutes) and virucidal (5 log10 reduction in 5 minutes) 663. Synergistic sporicidal effects were observed when spores were exposed to a combination of hydrogen peroxide (5.9%–23.6%) and peracetic acid 664. Other studies demonstrated the antiviral activity of hydrogen peroxide against rhinovirus 665. The time required for inactivating three serotypes of rhinovirus using a 3% hydrogen peroxide solution was 6–8 minutes; this time increased with decreasing concentrations (18-20 minutes at 1.5%, 50–60 minutes at 0.75%).

 Top of Page

Concentrations of hydrogen peroxide from 6% to 25% show promise as chemical sterilants. The product marketed as a sterilant is a premixed, ready-to-use chemical that contains 7.5% hydrogen peroxide and 0.85% phosphoric acid (to maintain a low pH) 69. The mycobactericidal activity of 7.5% hydrogen peroxide has been corroborated in a study showing the inactivation of >105 multidrug-resistant M. tuberculosis after a 10-minute exposure 666. Thirty minutes were required for >99.9% inactivation of poliovirus and HAV 667. Three percent and 6% hydrogen peroxide were unable to inactivate HAV in 1 minute in a carrier test 58. When the effectiveness of 7.5% hydrogen peroxide at 10 minutes was compared with 2% alkaline glutaraldehyde at 20 minutes in manual disinfection of endoscopes, no significant difference in germicidal activity was observed 668. ). No complaints were received from the nursing or medical staff regarding odor or toxicity. In one study, 6% hydrogen peroxide (unused product was 7.5%) was more effective in the high-level disinfection of flexible endoscopes than was the 2% glutaraldehyde solution 456. A new, rapid-acting 13.4% hydrogen peroxide formulation (that is not yet FDA-cleared) has demonstrated sporicidal, mycobactericidal, fungicidal, and virucidal efficacy. Manufacturer data demonstrate that this solution sterilizes in 30 minutes and provides high-level disinfection in 5 minutes669. This product has not been used long enough to evaluate material compatibility to endoscopes and other semicritical devices, and further assessment by instrument manufacturers is needed.

 Top of Page

Under normal conditions, hydrogen peroxide is extremely stable when properly stored (e.g., in dark containers). The decomposition or loss of potency in small containers is less than 2% per year at ambient temperatures 670.

 Top of Page

Uses.

Commercially available 3% hydrogen peroxide is a stable and effective disinfectant when used on inanimate surfaces. It has been used in concentrations from 3% to 6% for disinfecting soft contact lenses (e.g., 3% for 2–3 hrs) 653, 671, 672, tonometer biprisms 513, ventilators 673, fabrics 397, and endoscopes 456. Hydrogen peroxide was effective in spot-disinfecting fabrics in patients’ rooms 397. Corneal damage from a hydrogen peroxide-soaked tonometer tip that was not properly rinsed has been reported 674. Hydrogen peroxide also has been instilled into urinary drainage bags in an attempt to eliminate the bag as a source of bladder bacteriuria and environmental contamination 675. Although the instillation of hydrogen peroxide into the bag reduced microbial contamination of the bag, this procedure did not reduce the incidence of catheter-associated bacteriuria 675.

 Top of Page

A chemical irritation resembling pseudomembranous colitis caused by either 3% hydrogen peroxide or a 2% glutaraldehyde has been reported 621. An epidemic of pseudomembrane-like enteritis and colitis in seven patients in a gastrointestinal endoscopy unit also has been associated with inadequate rinsing of 3% hydrogen peroxide from the endoscope 676.

 Top of Page

As with other chemical sterilants, dilution of the hydrogen peroxide must be monitored by regularly testing the minimum effective concentration (i.e., 7.5%–6.0%). Compatibility testing by Olympus America of the 7.5% hydrogen peroxide found both cosmetic changes (e.g., discoloration of black anodized metal finishes) 69 and functional changes with the tested endoscopes (Olympus, written communication, October 15, 1999).

 Top of Page

Iodophors

Overview.

Iodine solutions or tinctures long have been used by health professionals primarily as antiseptics on skin or tissue. Iodophors, on the other hand, have been used both as antiseptics and disinfectants. FDA has not cleared any liquid chemical sterilant or high-level disinfectants with iodophors as the main active ingredient. An iodophor is a combination of iodine and a solubilizing agent or carrier; the resulting complex provides a sustained-release reservoir of iodine and releases small amounts of free iodine in aqueous solution. The best-known and most widely used iodophor is povidone-iodine, a compound of polyvinylpyrrolidone with iodine. This product and other iodophors retain the germicidal efficacy of iodine but unlike iodine generally are nonstaining and relatively free of toxicity and irritancy 677, 678.

 Top of Page

Several reports that documented intrinsic microbial contamination of antiseptic formulations of povidone-iodine and poloxamer-iodine 679-681 caused a reappraisal of the chemistry and use of iodophors682. “Free” iodine (I2) contributes to the bactericidal activity of iodophors and dilutions of iodophors demonstrate more rapid bactericidal action than does a full-strength povidone-iodine solution. The reason for the observation that dilution increases bactericidal activity is unclear, but dilution of povidone-iodine might weaken the iodine linkage to the carrier polymer with an accompanying increase of free iodine in solution 680. Therefore, iodophors must be diluted according to the manufacturers’ directions to achieve antimicrobial activity.

 Top of Page

Mode of Action.

Iodine can penetrate the cell wall of microorganisms quickly, and the lethal effects are believed to result from disruption of protein and nucleic acid structure and synthesis.

 Top of Page

Microbicidal Activity.

Published reports on the in vitro antimicrobial efficacy of iodophors demonstrate that iodophors are bactericidal, mycobactericidal, and virucidal but can require prolonged contact times to kill certain fungi and bacterial spores 14, 71-73, 290, 683-686. Three brands of povidone-iodine solution have demonstrated more rapid kill (seconds to minutes) of S. aureus and M. chelonae at a 1:100 dilution than did the stock solution 683. The virucidal activity of 75–150 ppm available iodine was demonstrated against seven viruses 72. Other investigators have questioned the efficacy of iodophors against poliovirus in the presence of organic matter 685and rotavirus SA-11 in distilled or tapwater 290. Manufacturers’ data demonstrate that commercial iodophors are not sporicidal, but they are tuberculocidal, fungicidal, virucidal, and bactericidal at their recommended use-dilution.

 Top of Page

Uses.

Besides their use as an antiseptic, iodophors have been used for disinfecting blood culture bottles and medical equipment, such as hydrotherapy tanks, thermometers, and endoscopes. Antiseptic iodophors are not suitable for use as hard-surface disinfectants because of concentration differences. Iodophors formulated as antiseptics contain less free iodine than do those formulated as disinfectants 376. Iodine or iodine-based antiseptics should not be used on silicone catheters because they can adversely affect the silicone tubing 687.

 Top of Page

Ortho-phthalaldehyde (OPA)

Overview.

Ortho-phthalaldehyde is a high-level disinfectant that received FDA clearance in October 1999. It contains 0.55% 1,2-benzenedicarboxaldehyde (OPA). OPA solution is a clear, pale-blue liquid with a pH of 7.5. (Tables 4 and 5)

 Top of Page

Mode of Action.

Preliminary studies on the mode of action of OPA suggest that both OPA and glutaraldehyde interact with amino acids, proteins, and microorganisms. However, OPA is a less potent cross-linking agent. This is compensated for by the lipophilic aromatic nature of OPA that is likely to assist its uptake through the outer layers of mycobacteria and gram-negative bacteria 688-690. OPA appears to kill spores by blocking the spore germination process 691.

 Top of Page

Microbicidal Activity.

Studies have demonstrated excellent microbicidal activity in vitro 69, 100, 271, 400, 692-703. For example, OPA has superior mycobactericidal activity (5-log10 reduction in 5 minutes) to glutaraldehyde. The mean times required to produce a 6-log10 reduction for M. bovis using 0.21% OPA was 6 minutes, compared with 32 minutes using 1.5% glutaraldehyde 693. OPA showed good activity against the mycobacteria tested, including the glutaraldehyde-resistant strains, but 0.5% OPA was not sporicidal with 270 minutes of exposure. Increasing the pH from its unadjusted level (about 6.5) to pH 8 improved the sporicidal activity of OPA 694. The level of biocidal activity was directly related to the temperature. A greater than 5-log10 reduction of B. atrophaeus spores was observed in 3 hours at 35°C, than in 24 hours at 20°C. Also, with an exposure time ≤5 minutes, biocidal activity decreased with increasing serum concentration. However, efficacy did not differ when the exposure time was ≥10 minutes 697. In addition, OPA is effective (>5-log10 reduction) against a wide range of microorganisms, including glutaraldehyde-resistant mycobacteria and B. atrophaeus spores 694.

 Top of Page

The influence of laboratory adaptation of test strains, such as P. aeruginosa, to 0.55% OPA has been evaluated. Resistant and multiresistant strains increased substantially in susceptibility to OPA after laboratory adaptation (log10 reduction factors increased by 0.54 and 0.91 for resistant and multiresistant strains, respectively) 704. Other studies have found naturally occurring cells of P. aeurginosa were more resistant to a variety of disinfectants than were subcultured cells 705.

 Top of Page

Uses.

OPA has several potential advantages over glutaraldehyde. It has excellent stability over a wide pH range (pH 3–9), is not a known irritant to the eyes and nasal passages 706, does not require exposure monitoring, has a barely perceptible odor, and requires no activation. OPA, like glutaraldehyde, has excellent material compatibility. A potential disadvantage of OPA is that it stains proteins gray (including unprotected skin) and thus must be handled with caution 69. However, skin staining would indicate improper handling that requires additional training and/or personal protective equipment (e.g., gloves, eye and mouth protection, and fluid-resistant gowns). OPA residues remaining on inadequately water-rinsed transesophageal echo probes can stain the patient’s mouth 707. Meticulous cleaning, using the correct OPA exposure time (e.g., 12 minutes) and copious rinsing of the probe with water should eliminate this problem. The results of one study provided a basis for a recommendation that rinsing of instruments disinfected with OPA will require at least 250 mL of water per channel to reduce the chemical residue to a level that will not compromise patient or staff safety (<1 ppm) 708. Personal protective equipment should be worn when contaminated instruments, equipment, and chemicals are handled 400. In addition, equipment must be thoroughly rinsed to prevent discoloration of a patient’s skin or mucous membrane.

 Top of Page

In April 2004, the manufacturer of OPA disseminated information to users about patients who reportedly experienced an anaphylaxis-like reaction after cystoscopy where the scope had been reprocessed using OPA. Of approximately 1 million urologic procedures performed using instruments reprocessed using OPA, 24 cases (17 cases in the United States, six in Japan, one in the United Kingdom) of anaphylaxis-like reactions have been reported after repeated cystoscopy (typically after four to nine treatments). Preventive measures include removal of OPA residues by thorough rinsing and not using OPA for reprocessing urologic instrumentation used to treat patients with a history of bladder cancer (Nevine Erian, personal communication, June 4, 2004; Product Notification, Advanced Sterilization Products, April 23, 2004) 709.

 Top of Page

A few OPA clinical studies are available. In a clinical-use study, OPA exposure of 100 endoscopes for 5 minutes resulted in a >5-log10 reduction in bacterial load. Furthermore, OPA was effective over a 14-day use cycle 100. Manufacturer data show that OPA will last longer in an automatic endoscope reprocessor before reaching its MEC limit (MEC after 82 cycles) than will glutaraldehyde (MEC after 40 cycles) 400. High-pressure liquid chromatography confirmed that OPA levels are maintained above 0.3% for at least 50 cycles 706, 710. OPA must be disposed in accordance with local and state regulations. If OPA disposal through the sanitary sewer system is restricted, glycine (25 grams/gallon) can be used to neutralize the OPA and make it safe for disposal.

 Top of Page

The high-level disinfectant label claims for OPA solution at 20°C vary worldwide (e.g., 5 minutes in Europe, Asia, and Latin America; 10 minutes in Canada and Australia; and 12 minutes in the United States). These label claims differ worldwide because of differences in the test methodology and requirements for licensure. In an automated endoscope reprocessor with an FDA-cleared capability to maintain solution temperatures at 25°C, the contact time for OPA is 5 minutes.

 Top of Page

Peracetic Acid

Overview.

Peracetic, or peroxyacetic, acid is characterized by rapid action against all microorganisms. Special advantages of peracetic acid are that it lacks harmful decomposition products (i.e., acetic acid, water, oxygen, hydrogen peroxide), enhances removal of organic material 711, and leaves no residue. It remains effective in the presence of organic matter and is sporicidal even at low temperatures (Tables 4 and 5). Peracetic acid can corrode copper, brass, bronze, plain steel, and galvanized iron but these effects can be reduced by additives and pH modifications. It is considered unstable, particularly when diluted; for example, a 1% solution loses half its strength through hydrolysis in 6 days, whereas 40% peracetic acid loses 1%–2% of its active ingredients per month 654.

 Top of Page

Mode of Action.

Little is known about the mechanism of action of peracetic acid, but it is believed to function similarly to other oxidizing agents—that is, it denatures proteins, disrupts the cell wall permeability, and oxidizes sulfhydryl and sulfur bonds in proteins, enzymes, and other metabolites 654.

 Top of Page

Microbicidal Activity.

Peracetic acid will inactivate gram-positive and gram-negative bacteria, fungi, and yeasts in ≤5 minutes at <100 ppm. In the presence of organic matter, 200–500 ppm is required. For viruses, the dosage range is wide (12–2250 ppm), with poliovirus inactivated in yeast extract in 15 minutes with 1,500–2,250 ppm. In one study, 3.5% peracetic acid was ineffective against HAV after 1-minute exposure using a carrier test 58. Peracetic acid (0.26%) was effective (log10 reduction factor >5) against all test strains of mycobacteria (M. tuberculosis, M. avium-intracellulare, M. chelonae, and M. fortuitum) within 20–30 minutes in the presence or absence of an organic load 607, 712. With bacterial spores, 500–10,000 ppm (0.05%–1%) inactivates spores in 15 seconds to 30 minutes using a spore suspension test 654, 659, 713-715.

 Top of Page

Uses.

An automated machine using peracetic acid to chemically sterilize medical (e.g., endoscopes, arthroscopes), surgical, and dental instruments is used in the United States716-718. As previously noted, dental handpieces should be steam sterilized. The sterilant, 35% peracetic acid, is diluted to 0.2% with filtered water at 50°C. Simulated-use trials have demonstrated excellent microbicidal activity 111, 718-722, and three clinical trials have demonstrated both excellent microbial killing and no clinical failures leading to infection90, 723, 724. The high efficacy of the system was demonstrated in a comparison of the efficacies of the system with that of ethylene oxide. Only the peracetic acid system completely killed 6 log10 of M. chelonae, E. faecalis, and B. atrophaeus spores with both an organic and inorganic challenge722. An investigation that compared the costs, performance, and maintenance of urologic endoscopic equipment processed by high-level disinfection (with glutaraldehyde) with those of the peracetic acid system reported no clinical differences between the two systems. However, the use of this system led to higher costs than the high-level disinfection, including costs for processing ($6.11 vs. $0.45 per cycle), purchasing and training ($24,845 vs. $16), installation ($5,800 vs. $0), and endoscope repairs ($6,037 vs. $445) 90. Furthermore, three clusters of infection using the peracetic acid automated endoscope reprocessor were linked to inadequately processed bronchoscopes when inappropriate channel connectors were used with the system 725. These clusters highlight the importance of training, proper model-specific endoscope connector systems, and quality-control procedures to ensure compliance with endoscope manufacturer recommendations and professional organization guidelines. An alternative high-level disinfectant available in the United Kingdom contains 0.35% peracetic acid. Although this product is rapidly effective against a broad range of microorganisms 466, 726, 727, it tarnishes the metal of endoscopes and is unstable, resulting in only a 24-hour use life 727.

 Top of Page

Peracetic Acid and Hydrogen Peroxide

Overview.

Two chemical sterilants are available that contain peracetic acid plus hydrogen peroxide (i.e., 0.08% peracetic acid plus 1.0% hydrogen peroxide [no longer marketed]; and 0.23% peracetic acid plus 7.35% hydrogen peroxide (Tables 4 and 5).

 Top of Page

Microbicidal Activity.

The bactericidal properties of peracetic acid and hydrogen peroxide have been demonstrated 728. Manufacturer data demonstrated this combination of peracetic acid and hydrogen peroxide inactivated all microorganisms except bacterial spores within 20 minutes. The 0.08% peracetic acid plus 1.0% hydrogen peroxide product effectively inactivated glutaraldehyde-resistant mycobacteria729.

 Top of Page

Uses.

The combination of peracetic acid and hydrogen peroxide has been used for disinfecting hemodialyzers 730. The percentage of dialysis centers using a peracetic acid-hydrogen peroxide-based disinfectant for reprocessing dialyzers increased from 5% in 1983 to 56% in 1997249. Olympus America does not endorse use of 0.08% peracetic acid plus 1.0% hydrogen peroxide (Olympus America, personal communication, April 15, 1998) on any Olympus endoscope because of cosmetic and functional damage and will not assume liability for chemical damage resulting from use of this product. This product is not currently available. FDA has cleared a newer chemical sterilant with 0.23% peracetic acid and 7.35% hydrogen peroxide (Tables 4 and 5). After testing the 7.35% hydrogen peroxide and 0.23% peracetic acid product, Olympus America concluded it was not compatible with the company’s flexible gastrointestinal endoscopes; this conclusion was based on immersion studies where the test insertion tubes had failed because of swelling and loosening of the black polymer layer of the tube (Olympus America, personal communication, September 13, 2000).

 Top of Page

Phenolics

Overview.

Phenol has occupied a prominent place in the field of hospital disinfection since its initial use as a germicide by Lister in his pioneering work on antiseptic surgery. In the past 30 years, however, work has concentrated on the numerous phenol derivatives or phenolics and their antimicrobial properties. Phenol derivatives originate when a functional group (e.g., alkyl, phenyl, benzyl, halogen) replaces one of the hydrogen atoms on the aromatic ring. Two phenol derivatives commonly found as constituents of hospital disinfectants are ortho-phenylphenol and ortho-benzyl-para-chlorophenol. The antimicrobial properties of these compounds and many other phenol derivatives are much improved over those of the parent chemical. Phenolics are absorbed by porous materials, and the residual disinfectant can irritate tissue. In 1970, depigmentation of the skin was reported to be caused by phenolic germicidal detergents containing para-tertiary butylphenol and para-tertiary amylphenol 731.

 Top of Page

Mode of Action.

In high concentrations, phenol acts as a gross protoplasmic poison, penetrating and disrupting the cell wall and precipitating the cell proteins. Low concentrations of phenol and higher molecular-weight phenol derivatives cause bacterial death by inactivation of essential enzyme systems and leakage of essential metabolites from the cell wall 732.

 Top of Page

Microbicidal Activity.

Published reports on the antimicrobial efficacy of commonly used phenolics showed they were bactericidal, fungicidal, virucidal, and tuberculocidal 14, 61, 71, 73, 227, 416, 573, 732-738. One study demonstrated little or no virucidal effect of a phenolic against coxsackie B4, echovirus 11, and poliovirus 1 736. Similarly, 12% ortho-phenylphenol failed to inactivate any of the three hydrophilic viruses after a 10-minute exposure time, although 5% phenol was lethal for these viruses 72. A 0.5% dilution of a phenolic (2.8% ortho-phenylphenol and 2.7% ortho-benzyl-para-chlorophenol) inactivated HIV 227 and a 2% solution of a phenolic (15% ortho-phenylphenol and 6.3% para-tertiary-amylphenol) inactivated all but one of 11 fungi tested 71.

 Top of Page

Manufacturers’ data using the standardized AOAC methods demonstrate that commercial phenolics are not sporicidal but are tuberculocidal, fungicidal, virucidal, and bactericidal at their recommended use-dilution. Attempts to substantiate the bactericidal label claims of phenolics using the AOAC Use-Dilution Method occasionally have failed 416, 737. However, results from these same studies have varied dramatically among laboratories testing identical products.

 Top of Page

Uses.

Many phenolic germicides are EPA-registered as disinfectants for use on environmental surfaces (e.g., bedside tables, bedrails, and laboratory surfaces) and noncritical medical devices. Phenolics are not FDA-cleared as high-level disinfectants for use with semicritical items but could be used to preclean or decontaminate critical and semicritical devices before terminal sterilization or high-level disinfection.

The use of phenolics in nurseries has been questioned because of hyperbilirubinemia in infants placed in bassinets where phenolic detergents were used 739. In addition, bilirubin levels were reported to increase in phenolic-exposed infants, compared with nonphenolic-exposed infants, when the phenolic was prepared according to the manufacturers’ recommended dilution 740. If phenolics are used to clean nursery floors, they must be diluted as recommended on the product label. Phenolics (and other disinfectants) should not be used to clean infant bassinets and incubators while occupied. If phenolics are used to terminally clean infant bassinets and incubators, the surfaces should be rinsed thoroughly with water and dried before reuse of infant bassinets and incubators 17.

 Top of Page

Quaternary Ammonium Compounds

Overview.

The quaternary ammonium compounds are widely used as disinfectants. Health-care–associated infections have been reported from contaminated quaternary ammonium compounds used to disinfect patient-care supplies or equipment, such as cystoscopes or cardiac catheters 741, 742. The quaternaries are good cleaning agents, but high water hardness 743 and materials such as cotton and gauze pads can make them less microbicidal because of insoluble precipitates or cotton and gauze pads absorb the active ingredients, respectively. One study showed a significant decline (~40%–50% lower at 1 hour) in the concentration of quaternaries released when cotton rags or cellulose-based wipers were used in the open-bucket system, compared with the nonwoven spunlace wipers in the closed-bucket system.744 As with several other disinfectants (e.g., phenolics, iodophors) gram-negative bacteria can survive or grow in them 404.

Chemically, the quaternaries are organically substituted ammonium compounds in which the nitrogen atom has a valence of 5, four of the substituent radicals (R1-R4) are alkyl or heterocyclic radicals of a given size or chain length, and the fifth (X) is a halide, sulfate, or similar radical 745. Each compound exhibits its own antimicrobial characteristics, hence the search for one compound with outstanding antimicrobial properties. Some of the chemical names of quaternary ammonium compounds used in healthcare are alkyl dimethyl benzyl ammonium chloride, alkyl didecyl dimethyl ammonium chloride, and dialkyl dimethyl ammonium chloride. The newer quaternary ammonium compounds (i.e., fourth generation), referred to as twin-chain or dialkyl quaternaries (e.g. didecyl dimethyl ammonium bromide and dioctyl dimethyl ammonium bromide), purportedly remain active in hard water and are tolerant of anionic residues 746.

A few case reports have documented occupational asthma as a result of exposure to benzalkonium chloride 747.

Mode of Action.

The bactericidal action of the quaternaries has been attributed to the inactivation of energy-producing enzymes, denaturation of essential cell proteins, and disruption of the cell membrane746. Evidence exists that supports these and other possibilities 745 748.

Microbicidal Activity.

Results from manufacturers’ data sheets and from published scientific literature indicate that the quaternaries sold as hospital disinfectants are generally fungicidal, bactericidal, and virucidal against lipophilic (enveloped) viruses; they are not sporicidal and generally not tuberculocidal or virucidal against hydrophilic (nonenveloped) viruses14, 54-56, 58, 59, 61, 71, 73, 186, 297, 748, 749. The poor mycobactericidal activities of quaternary ammonium compounds have been demonstrated 55, 73. Quaternary ammonium compounds (as well as 70% isopropyl alcohol, phenolic, and a chlorine-containing wipe [80 ppm]) effectively (>95%) remove and/or inactivate contaminants (i.e., multidrug-resistant S. aureus, vancomycin-resistant Entercoccus, P. aeruginosa) from computer keyboards with a 5-second application time. No functional damage or cosmetic changes occurred to the computer keyboards after 300 applications of the disinfectants 45.

Attempts to reproduce the manufacturers’ bactericidal and tuberculocidal claims using the AOAC tests with a limited number of quaternary ammonium compounds occasionally have failed 73, 416, 737. However, test results have varied extensively among laboratories testing identical products 416, 737.

Uses.

The quaternaries commonly are used in ordinary environmental sanitation of noncritical surfaces, such as floors, furniture, and walls. EPA-registered quaternary ammonium compounds are appropriate to use for disinfecting medical equipment that contacts intact skin (e.g., blood pressure cuffs).

 Top of Page

TOP