Guideline for Disinfection and Sterilization in Healthcare Facilities (2008)
Tables and Figure
Table 11. Comparative evaluation of the microbicidal activity of low-temperature sterilization technology of carriers sterilized by various low-temperature sterilization technologies (based on tests of inoculated carriers in lab setting)
Challenge | Ethylene Oxide 12/88 | 100% Ethylene Oxide | HCFC – Ethylene Oxide | Hydrogen Peroxide Gas Plasma 100 | Hydrogen Peroxide Gas Plasma 100S | Peracetic Acid | Reference |
---|---|---|---|---|---|---|---|
No salt or serum1 | 100% | 100% | 96% | 100% | No Data | No Data | Alfa 721 |
10% serum and 0.65% salt2 | 97% | 60% | 95% | 37% | No Data | No Data | Alfa 721 |
Lumen (125 cm long × 3 mm wide) without serum or salt1 | No Data | 96% | 96% | No Data | No Data | No Data | Alfa 721 |
Lumen (125 cm long × 3 mm wide) with 10% serum and 0.65% salt2 | 44% | 40% | 49% | 35% | No Data | 100%1 | Alfa 721 |
Lumen (40 cm long × 3 mm wide)3 | ND | ND | 100% | 95% | 100% | 8% | Rutala 856 |
Lumen (40 cm long × 2 mm wide)3 | ND | ND | 100% | 93% | 100% | No Data | Rutala 856 |
Lumen (40 cm long × 1 mm wide)3 | ND | ND | 100% | 26% | 100% | No Data | Rutala 856 |
Lumen (40 cm long × 3 mm wide)4 | ND | ND | 100% | 100% | 100% | No Data | Rutala 856 |
Modified from Rutala. 825
HCFC hydrochlorofluorocarbon
1 Test organisms included Enterococcus faecalis, Mycobacterium chelonae, and Bacillus atrophaeus spores.
2 Test organisms included E. faecalis, P. aeruginosa, E. coli, M. chelonae, B. atrophaeus spores, G. stearothermophilus spores, and B. circulans spores.
3 Test organism was G. stearothermophilus spores. The lumen test units had a removable 5 cm center piece (1.2 cm diameter) of stainless steel sealed to the narrower steel tubing by hard rubber septums.
4 Test organism was G. stearothermophilus spores. The lumen test unit was a straight stainless steel tube.